4-40 CONTROL ITEMS
GGS-000548-01E iPASOLINK EX Advanced: Operation & Maintenance
4. Set the appropriate values, then click the OK button.
Figure 4-59 MODEM Maintenance Control Box
5. Warning dialog box appears. Click the OK button.
Figure 4-60 Warning Dialog Box
6. Information dialog box appears. Click OK button.
Figure 4-61 Information Dialog Box
Table 4-6 CW Control Parameters
Parameter Value Description
CW Control On Executes the controlling CW.
Off Releases the controlling CW. [default]
Release Time No Limit Specifies no limitation to auto recovery. (Not recommended.) NOTE: These
values are not
available for
the local
connection.
90 [s] Provides 90 seconds before executing the auto-recovery.
180 [s] Provides 180 seconds before executing the auto-recovery.
300 [s] Provides 300 seconds before executing the auto-recovery.
60 [min] Provides 60 minutes before executing the auto-recovery.
12 [h] Provides 12 hours before executing the auto-recovery.