Issue 1.2 UNIVERGE SV9100
4 - 6 Installing the SV9100 Blades
The system automatically recognizes each blade installed in the
system. If a blade has previously been installed in a slot and another
type of blade is to be installed in that same slot, the blade must first
be removed from the chassis and then the slot definition removed
using Program 90-05 prior to installing the new blade.
This same condition applies to extensions and other devices
connected to the system. For example, if a port was previously used
for a telephone and a DSS Console is to be installed in that same
port, it must first be undefined in Program 10-03 before the console
is connected.
2.2.3 Order of Installing Trunk Blades
2.2.3.1 Installing GCD-4COTA, GCD-4DIOPB, GCD-4ODTB or
GCD-2BRIA blades
The order in which trunk blades are physically inserted
determines the numbering plan.
Table 4-2 Adding Daughter Board to Chassis Example
Initial Blade Updated Blade
Blade
Slot #
Blade
Extension
Numbers
Blade
Slot #
Blade
Extension
Numbers
1 GCD-16DLCA 200~215 1 GCD-16DLCA 200~215
2 GCD-8DLCA
(no daughter
board)
216~223 2 — —
3 GCD-16DLCA 224~239 3 GCD-16DLCA 224~239
— — — 4 GCD-8DLCA
(with daughter
board)
240~255
To avoid unexpected extension/trunk
numbering if the VoIP or Voice Mail
board registers with the system first,
install these boards after
the other types
of extension and trunk blades have been
installed.