EasyManua.ls Logo

NEC Univerge SV9100 - Installing the ADA-L UNIT

NEC Univerge SV9100
478 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV9100 Issue 1.2
System Hardware Manual 6 - 35
11.3.2 Installing the ADA-L UNIT
Perform the following steps to connect the ADA-L UNIT to the
Bottom Option Interface located underneath the DTL/ITL multiline
terminal.
. Only one ADA-L UNIT can be installed at a time.
1. Unplug the line cord from the keyset.
2. Turn the DTL/ITL multiline terminal upside down.
3. Lower the tilt leg to the first position (refer to Figure 6-24
Separate Tilt Leg from Leg Support).
Dip
Switches
(DSW)
DSW 1
Output Hook Signal to External Device
On = Output
Off = No Output (Default)
DSW 2
Record Confirmation Tone
On = Tone On
Off = Tone Off (Default)
DSW 3
and
DSW 4
Use T1/T2
On = Disable (Default)
Off = Enable
. Do not connect T1 and T2 when DSW switches 3 and 4 are On.
Figure 6-24 Separate Tilt Leg from Leg Support
Table 6-3 ADA-L Unit Switch Settings (Continued)
Switch Description/Settings
To prevent possible damage to the ADA-L
UNIT or the DTL/ITL multiline terminal
during installation or removal, disconnect
the line cord/LAN cable and the AC/DC
adapter from the DTL/ITL multiline terminal.
Stoppers
Tilt Leg

Table of Contents