Issue 1.2 UNIVERGE SV9100
6 - 34 Installing SV9100 Optional Equipment
11.3.1 ADA-L UNIT Switch Settings
Figure 6-23 ADA-L UNIT shows the location of the switches. The dip
switches (DSW) allow a technician to configure the unit for specific
settings.
To provide control to the recorder or to enable/disable the record start warning
tones, refer to Table 6-3 ADA-L Unit Switch Settings.
Figure 6-23 ADA-L UNIT
Table 6-3 ADA-L Unit Switch Settings
Switch Description/Settings
SW1
SW1-1 Connects to Multiline Terminal
Connect = Default
SW1-2 Not Used
SW2
SW2-1 Sets External Equipment Impedance to 600 Ω
SW2-2 Used for Complex Impedance Devices
(< 30 Ω Input Impedance)
Due to location, set switches prior to installation of
ADA-L on DT Series multiline terminal.