EasyManua.ls Logo

NEC Univerge SV9100 - Night Mode Selection; Night Mode Selector Switch; Connecting a Night Mode Selector Switch; Section 10 Telephone Labeling

NEC Univerge SV9100
478 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV9100 Issue 1.2
System Hardware Manual 6 - 27
SECTION 9 NIGHT MODE SELECTION
9.1 Night Mode Selector Switch
The Night Mode Switch relay closes when the system detects either an open
or closure on the MISC block NIGHT SW terminals. Maximum 48v DC is
output to the switch when open, and 7mA DC when shorted.
9.2 Connecting a Night Mode Selector Switch
1. Connect the night switch mechanism to the appropriate PGD circuit set
as sensor detector in PRG10-41.
. 10-41-01 = Slot number of DLCA card PGDAD is connected to
. 10-41-02 = port number of DLCA card PGDAD is connected to
. 10-41-03 = sensor circuit number
2. Configure PRG12-01-03 to define the Night Mode the system will use
when the switch is closed.
3. Configure PRG12-01-04 to define the Sensor Circuit to be used as the
switching relay.
SECTION 10 TELEPHONE LABELING
10.1 DESI Printer Sheets
Telephones can be easily labeled by removing the plastic faceplate. These
labels can be printed by hand, typewriter, or printing DESI labels. Labels for
this are on 8 1/2 x 11” paper, which allows for easy printing by any printer – dot
matrix, laser, etc.
DESI Printer Sheets are available for the following:
Economy 2E – DESI ITL/DTL-2E (25 PKG)
Economy 6DE – DESI ITL/DTL-6DE (25 PKG)
All Value Telephones – DESI ITL/DTL-12D/24D (25 PKG)
8LK – DESI ITL/DTL 8LK (25 PKG)
60 DSS – DESI DCL-60 (25 PKG)
Clear Side Panel – DESI ITL/DTL-SIDE (25 PKG)
LCD Value, Clear Side – DESI ITL/DTL-SIDE-LCDV (25 PKG)

Table of Contents

Other manuals for NEC Univerge SV9100

Related product manuals