4.4.2 Installation
These daughter boards can be installed on the GCD-4LCA or
GCD-8LCA blades.
To install the GPZ-4LCA
/GPZ-8LCE:
1. Included with the SLIDB are four plastic spacers. Install the
plastic spacers onto either the GCD-4LCA or GCD-8LCA.
Make sure to attach the spacers so that they extend out on the
side of the daughter board which has the CN1 connector.
Refer to Figure 4-12 Installing the GPZ-4LCA Daughter Board
on page 4-45.
2. Position the SLIDB CN1 connector over the CN4 connector on
the SLIU blade. Press the boards together, ensuring the plastic
spacers lock in place. Refer to Figure 4-12 Installing the
GPZ-4LCA Daughter Board on page 4-45.
3. Install the SLIU blade into the slot on the chassis.
When connecting a fax machine or analog
modem, make sure to set Program 15-03-03 to
1 (special terminal) to avoid communication
problems.
The SLIU and SLIDB are categorized as
TNV2. With this designation, off-premise
wiring is not acceptable. Any cabling to the
SLIDB PCB must be within the building – no
outside cabling is permitted.
Branch connection is not acceptable.