UNIVERGE SV9100 Issue 1.2
System Hardware Manual 2 - 21
AC240V Power Supply:
Dedicated 15 Amp circuit
Power Requirements: 230 VAC @ 15A Controlling/Base Chassis
Power Consumption: Base Chassis=263VA, Expansion
Chassis=263VA, total 1060VA
Input Voltage: 90VAC to 264VAC
(Rated Voltage: 100VAC/120VAC/220VAC/230-240VAC)
Frequency: 47Hz - 63Hz (Rated frequency: 50/60Hz)
Phase and Wire: Single Phase, 2 Line + PE Type
Grounding Requirements: No. 14 AWG copper wire
Feeding Voltage: D
term
/OPX/DID: -48V
SLT: 25mA / -28V
With input voltage of 230 VAC and with full load conditions:
. Base chassis can refer to either 9.5” or 19” chassis
Output Power: Base chassis=130W, Expansion chassis=130W, total
520W
AC Input I: Base chassis=1.15A, Expansion chassis=1.15A, total 4.6A
VA @ 230V: Base chassis=276VA, Expansion chassis=276VA, total
1104VA
KWh @ AC Input I x 230V/1000: Base chassis=0.276 KWh,
Expansion chassis=0.276 KWh, total 1.104 KWh
BTU (KWh x 3413): Base chassis=
942 BTU, Expansion chassis=942
BTU
, total 3768 BTU (at 240Vac)
A dedicated outlet, separately fused and grounded for each chassis
should be installed
5.2.2 Power Supply Consumption
Table 2-18 Power Consumption
Chassis
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Basic Chassis – GCD-CP10 Chassis 2.19 A 96
130
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N
side).