4.7.2 Configuring the Digital Telephone for the Numbered Keypad
1. With the telephone not plugged in and the handset on-hook,
press the 4 and 6 buttons on the numbered keypad and
connect the telephone cable.
. This places the telephone into Service Class R/W mode. The MW LED
should be lit.
2. Press 2 on the numbered keypad to enter the Button Kit mode.
. The MW LED should flash.
3. Follow the directions below for the type of keypad installed:
4. Save to memory by pressing line key 2, 8, 14 or 20. The display
changes back to the Service Class R/W mode and the MW
LED will be lit Red.
5. Press Exit to return the telephone to the idle condition.
4.7.3 Configuring the IP Telephone for the Numbered Keypad
1. Enter the terminal’s program mode by pressing HOLD CONF
#.
Table 5-13 Numbered Keypad Type
Numbered Keypad Type Push LED Indication
Japanese 01 Line 1 LED on Red
Model A Telephone 02 Line 2 LED on Red
Model B UX5000 Telephone 03 Line 1 and 2 LED on Red
Call Center 04 Line 1 LED on Green
Hotel-1 05 Line 2 LED on Green
Hotel-2 06 Line 1 and 2 LED on Green
Retirement Home 07 Line 1 LED flashing Red
Japan 32-Button 08 Line 2 LED flashing Red
Japan Value 09 Line 1 and 2 LED flashing Red
Model A Value (retro) 10 Line 1 LED flashing Green
Model B Value 11 Line 2 LED flashing Green
Reserve 12 Line 1 and 2 LED flashing Green