UNIVERGE SV9100 Issue 1.2
System Hardware Manual 2 - 17
SECTION 5 SYSTEM REQUIREMENTS AND SPECIFICATIONS
5.1 Cabling
This section provides cabling requirements and specifications for various
equipment used in the SV9100 system.
Figure 2-4 Connecting the DLC Using Twisted 2-Pair Cable is a diagram of the
chassis connected with each of the multiline terminals and single line
telephones by a separate twisted 1-pair cable or 2-pair cable (only for Multiline
Termi n a l s ) .
Refer to the following tables for cabling requirements and specifications.
Table 2-12 DT300 Series Loop Resistance and Cable Length
Table 2-13 DT400 Series Loop Resistance and Cable Length
Table 2-14 DT700 Series Loop Resistance and Cable Length
Table 2-15 DT800 Series Loop Resistance and Cable Length
Table 2-16 Cable Connection Between the Analog Port and the Single Line
Equipment
Table 2-17 Cabling Requirements
Figure 2-4 Connecting the DLC Using Twisted 2-Pair Cable
Table 2-12 DT300 Series Loop Resistance and Cable Length
Terminal or Adapter
By Twisted 1-Pair
Cable (without
AC Adapter)
24 AWG
By Twisted 1-Pair
Cable (with AC
Adapter)
24 AWG
DTL-2E-1 (BK) TEL
1,969 ft (600m) 6,562 ft (2000m)
DTL-6DE-1 (BK) TEL
1,969 ft (600m) 6,562 ft (2000m)
DTL-8LD-1 (BK) TEL
DTL-8LD-1 (WH) TEL
1,969 ft (600m) 6,562 ft (2000m)
DTL-12BT-1 (BK) TEL
1,969 ft (600m) 6,562 ft (2000m)
DTL-12PA-1 (BK) TEL
1,969 ft (600m) 6,562 ft (2000m)
Multiline Terminal
Twisted 2-Pair Cable
DLC
RJ-11