Program 21 to 25
Xen Topaz Programming Manual 184
PROGRAM 22: INCOMING CALL SETUP
22-11: DID T
RANSLATION NUMBER CONVERSION
Input Data
IN
SA
SB
Conversion Table Number
1-2000
Prog. No. Item Input Data
Default
22-11-01
Received Number Max. 8 digits see Default
22-11-02
Target Number Max. 36 digits see Default
22-11-03
DID Name Max. 12 Characters No setting
22-11-04
Transfer Operation Mode
0 : No Transfer
1 : Busy
2 : No Answer
3 : Busy/ No Answer
0
22-11-05
Transfer Destination Number-
1
0 : No setting
1-25 : Incoming Ring Group
101 : DSPDB-VM
201-232 : Department Group
400 : VRS AA
401 : DISA
1000-1999 : Common ABB Dial (000-
999)
0
22-11-06
Transfer Destination Number-
2
0
22-11-07
Call Waiting
0 : Disable
1 : Enable
0
22-11-08
Maximum Number of DID
Calls
0-51 (0 : No limit) 0
22-11-09
Music on Hold Source
0 : MOH Tone
1 : BGM Source
2 : Music Source Port
0
22-11-10
Music Source Port Number 0-6 0
22-11-11
Ring Group Transfer
Enable (1) or disable (0) each
conversion tables’ ability to
follow the Ring Group pro-
gramming defined in Program
22-12-01 : DID Intercept
Ring Group.
If Program 22-11-05 : DID
Translation Number Conver-
sion, Transfer Destination
Number 1 and Program 22-
11-06 : DID Translation
Number Conversion, Trans-
fer Destination Number 2
are set, the priority of transfer-
ring will be in this order: Pro-
gram 22-11-05 then Program
22-11-06 then if Program 22-
11-11 is enabled, Program 22-
12-01.
0 : Disable
1 : Enable
1
Related
Program
22-04
22-05
25-02
40-06

Table of Contents