Program 40 to 92
Xen Topaz Programming Manual 269
PROGRAM 40: VOICE MAIL SETUP
40-05: M
ESSAGE NOTIFICATION SETUP
Description
Use Program 40-05 : Call Information Setup to define the message notification facility of the Voice Mail
(DSPDBU).
Input Data
Conditions
None
Feature Cross Reference
Voice Mail (DSPDB)
Telephone Programming Instructions
To enter data for Program 40-05 (Call Information Setup):
1. Enter the programming mode.
2. Enter 40 05
3. Enter the number of the item you want to program.
4. Enter data for the item you selected + HOLD.
5. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’ programming section.
IN
SA
SB COPY
Prog. No. Item Input Data Default
Related
Program
40-05-01 Maximum number of outgoing call
simultaneously
0-8 1
40-05-02 Trunk Route Number 0-25 1
40-05-03
ISDN Calling Party Number
0-9,*,#
(Max.16 digits)
No setting
40-05-04 Call interval for intercom call 1-30 minutes 10
40-05-05 Call interval for external call 1-30 minutes 10
40-05-06 Maximum number of intercom call 1-100 3
40-05-07 Maximum number of external call 1-100 3
40-05-01
SimultaneousMax1
40-05-xx
xxxxx