Program 40 to 92
Xen Topaz Programming Manual 301
PROGRAM 80: BASIC HARDWARE SETUP FOR SYSTEM
80-04: C
ALL PROCESS TONE DETECTOR SETUP
Default
Conditions
None
Feature Cross Reference
None
Telephone Programming Instructions
To enter data for Program 80-04(Call Progress Tone Detector Setup):
1. Enter the programming mode.
2. Enter 80 04
3. Enter the number of the item you want to program.
4. Select the Tone Detector Type number to be programmed by pressing the FLASH or the VOLUME
or VOLUME keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’ programming section.
MF
SA
SB
Prog. No.
Item
Type 1(DT) Type 2(BT) Type 3(RBT) Type 4 Type 5
80-04-01
Detect Level
0 (0..-
25dBm)
0 (0..-
25dBm)
0 (0..-25dBm) 0 0
80-04-02
Min. detect level 15 (-25dBm) 15 (-25dBm) 15 (-25dBm) 0 0
80-04-03
S/N ratio 4 (-20dB) 4 (-20dB) 4 (-20dB) 0 0
80-04-04
No tone time
132
(3990ms)
132
(3990ms)
132 (3990ms) 0 0
80-04-05
Pulse Count
1 1 1 0 0
80-04-06
ON min. time
63 (1920ms) 10 (330ms) 25 (780ms) 0 0
80-04-07
ON max. time
0 (No detect) 13 (420ms) 40 (1230ms) 0 0
80-04-08
OFF min. time
1 (60ms) 10 (330ms) 52 (1590ms) 0 0
80-04-09
OFF max. time
1 (60ms) 13 (420ms) 80 (2430ms) 0 0
80-04-10
-- Reserve --
1 1 1 0 0
80-04-11
-- Reserve --
0 0 0 0 0
80-04-01ToneRcv1
Detect Level 0
80-04-xxToneRcvx
xxxxx