Program 40 to 92
Xen Topaz Programming Manual 300
PROGRAM 80: BASIC HARDWARE SETUP FOR SYSTEM
80-04: C
ALL PROCESS TONE DETECTOR SETUP
Description
Use Program 80-04 : Call Progress Tone Detector Setup to define the various levels and timers for the
Call Progress Tone Detector.
Input Data
MF
SA
SB
Tone Detector Type Number
1 : - Reserve -
2 : Busy Tone for Trunk
3 : Ring Back Tone for Trunk
4,5 : -Reserve-
Prog. No. Item Input Data
Related
Program
80-04-01
Detect Level 0 : 0dBm…-25dBm
1 : -5dBm…-30dBm
2 : -10dBm…-35dBm
3 : -15dBm…-40dBm
4 : -20dBm…-45dBm
5 : -25dBm…-50dBm
6 : -30dBm…-55dBm
80-04-02
Min. detect level
0-15
detect level 0 : –10dBm(0) to –25dBm(15)
detect level 1 : –15dBm(0) to –30dBm(15)
detect level 2 : –20dBm(0) to –35dBm(15)
detect level 3 : –25dBm(0) to –40dBm(15)
detect level 4 : –30dBm(0) to –45dBm(15)
detect level 5 : –35dBm(0) to –50dBm(15)
detect level 6 : –40dBm(0) to –55dBm(15)
80-04-03
S/N ratio 0-4 (0dB…-20dB)
80-04-04 No tone time
0-255 (30+30-7650ms)
(0 : No detection)
80-04-05 Pulse Count
1-255
80-04-06 ON min. time
1-255 (30+30-7650ms)
80-04-07 ON max. time
0-255 (30+30-7650ms)
(0 : No detection)
80-04-08 OFF min. time
1-255 (30+30-7650ms)
80-04-09 OFF max. time
0-255 (30+30-7650ms)
(0 : No detection)
80-04-10 -- Reserve --
0-8
80-04-11 -- Reserve --
0-8