Program 40 to 92
Xen Topaz Programming Manual 303
PROGRAM 80: BASIC HARDWARE SETUP FOR TRUNK
81-01: A
NALOGUE TRUNK INITIAL DATA SETUP
Description
Use Program 81-01 : Analogue Trunk Initial Data Setup to define the various basic timers for the Trunk
Interface of 308M/308ME cards.
Input Data
IN
SA
SB
Prog. No. Item Input Data
Default
81-01-01
Companding method type
0 : ยต-law
1 : A-law
1(A-law)
81-01-02 Loop Current Detection Time
1-255(8-2040ms)
75(600ms)
81-01-03 Clear Signal (Open Loop) Detection Time
1-255(8-2040ms) 37(296ms)
81-01-04 Ring Signal Detection Min. Time
1-255(8-2040ms) 13(104ms)
81-01-05 Single Ringing Detection Min. Time
0-255(0,8-2040ms) 82(656ms)
81-01-06 Double Ringing Detection Min. Off Time
0-255 (0,8-2040mS) 13 (104ms)
81-01-07 Double Ringing Detection Max. Off Time
0-255 (0,8-2040mS) 75 (600ms)
81-01-08 Ringing Signal Not Detection Minimum
1-255 (8-2040mS) 88 (704ms)
81-01-09 Time Ringing Signal Stop Detection Time
1-255 (64-16320mS)
38(304ms)
81-01-10 Continuous Ringing Minimum Time
0-255 (0,8-2040mS)
25(200ms)
81-01-11 Continuous Ringing Maximum Time
0-255 (0,8-2040mS)
88(704ms)
81-01-12 AC Impedance Timer
1-255 (64-16320mS) 4 (256ms)
81-01-13 Grounding Time
1-255 (16-4080mS) 9 (144ms)
81-01-14
Flash (Hooking 1)
This sets the flash (Hooking 1) duration for
analogue trunk calls. See Program 14-02-04.
1-255 (16-4080mS) 6 (96ms)
81-01-15
Flash (Hooking 2)
This sets the flash (Hooking 2) duration for
analogue trunk calls. See Program 14-02-04.
1-255 (16-4080mS)
156(2496ms)
81-01-16 Pause Time
1-255(64-16320mS) 47(3008ms)
81-01-17 PFT Idle Detection Time
1-255(64-16320mS) 47(3008ms)
81-01-18 Grounding Start Time
1-255 (8-2040mS) 6 (48ms)
81-01-19 Grounding Start Give-up Time
1-255 (64-16320mS) 47 (3008ms)
81-01-20 Loop Reverse Detect Min. Time
1-255 (8-2040mS)
13 (104ms)
81-01-21 Loop Reverse Detect Max. Time
1-255 (8-2040mS) 107 (856ms)
81-01-22 Loop Disconnect Detect Min. Time
1-255 (8-2040mS)
63(504ms)
81-01-23
Loop Disconnect Detect Max. Time
1-255 (8-2040mS)
87(696ms)
81-01-24 On Hook Normal Detect Time
1-255 (8-2040mS)
3(24ms)
81-01-25 On Hook Reverse Detect Time
1-255 (8-2040mS) 2 (16ms)
81-01-26 On Hook Disconnect Detect Time
1-255 (16-4080mS) 188 (3008ms)