Program 12 to 15
Xen Topaz Programming Manual 65
PROGRAM 13: ABBREVIATED DIALLING
13-01: A
BBREVIATED DIALLING FUNCTION SETUP
Description
Use Program 13-01 : Abbreviated Dialling Function Setup to define the Abbreviated Dialling functions.
Input Data
Conditions
None
Feature Cross Reference
Abbreviated Dialling
Telephone Programming Instructions
To enter data for Program 13-01 (Abbreviated Dialling Function Setup):
1. Enter the programming mode.
2. Enter 13 01
3. Enter the number of the item you want to program.
4. Enter data for the item you selected + HOLD.
5. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you’ve exited that series’ programming section.
IN
SA
SB
Prog. No. Item Input data Default
Related
Program
13-01-01
Abbreviated Dialling Auto Out-
going Call Mode
0 : Trunk outgoing mode
1 : Extension outgoing mode
0 13-05
13-01-02 Station Abbreviated Dial
0 : Disable
1 : Enable
1 13-06
13-01-03
Number of Common Abbrevi-
ated Dialling Bins
100-2000
0 : No Common Abbreviated
Dialling Bins
(100 bins per 1 unit)
900 13-04
13-01-01
ABB Dial Mode 0
13-01-xx