Program 12 to 15
Xen Topaz Programming Manual 75
PROGRAM 14: TRUNK BASIC SETUP
14-02: A
NALOGUE TRUNK DATA SETUP
Description
Use Program 14-02 : Analogue Trunk Data Setup to set the basic options for each analogue trunk port.
Refer to the chart below for a description of each option, its range and default setting.
Input Data
IN
SA
SB
Trunk Port Number 1-51
Prog. No. Item Input data Default
Related
Program
14-02-01
Not Used
-
-
14-02-02
Ring Detect Type
This option to sets Extended Ring Detect or
Immediate Ring Detect for the trunk.
0 : Normal/Delayed
1 : Immediately
ringing
0
14-02-03
Flash Type
This option to select the Flash type (open loop
flash or ground). Always set this option for
open loop flash.
0 : Open Loop
Flash
1 : Ground
0
14-02-04
Flash for Timed Flash or Disconnect
This option lets you use Flash for Timed Flash
(Program 81-01-14) or Disconnect (Program
81-01-15). (A user implements Flash by
pressing the FLASH key while on a trunk call.)
0 : Timed Flash
1 : Disconnect
0
14-02-05
Not Used
14-02-06
Pause at 1
st
digit after line seize in manual
dial mode
0 : No Pause
1 : Pause
0 21-01-06
14-02-07
Not Used
-
-
14-02-08
Answering Condition 0 : Polarity
reversing
1 : Polarity revers-
ing or timer
1
21-01-03

Table of Contents