EasyManuals Logo

NSK Megatorque PS Series User Manual

NSK Megatorque PS Series
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #129 background imageLoading...
Page #129 background image
— 7-7 —
7.1.6. Stop: STP
This input stops all operations and prohibits entering positioning commands.
The input can be used for stopping the Motor in the middle of positioning and for the interlock
signal for a positioning start command.
Table 7-9: Signal logic of the input STP
Logic Description
OFF Positioning
ON Starts deceleration. Prohibits positioning.
Effects on the internal positioning command
An activation of the input STP in the middle of positioning caused by an internal command, such
as positioning, jogging and Home Return, the Motor decelerates and stops with the deceleration
specified at the positioning operation.
Once the input STP activates, the Motor decelerates and stops even the input STP is
released in the middle of deceleration.
When the parameter MD (STP move deceleration) is specified, the System compares the
deceleration between the value of parameter MB and MD and applies the higher deceleration.
(The System chooses the deceleration to stop the Motor quickly.)
Table 7-10: Parameter related to the input STP
Parameter Function
Initial
setting
Value range Unit
MD
Deceleration for input
STP
0.0
0.0: Applies the deceleration value currently
programmed in the positioning.
0.1 to 800.0
-
s
-2
The warning F5 (Program error) occurs if a program start command is ON during the STP is
ON.
Fig 7-6: Signal timing of the input STP (Internal command)
Motor motion
MA
MD
ON
OFF
Velocity in
CW or CCW
closed
open
Max. 2 ms
ON
OFF
Input STP
Starting
command
invalid
Max. 1 ms
Min. 1 ms
Max. 1 ms
RUN input
closed
open
Output WRN
Example: Warning F5: Program error
closed
open
Output BUSY
closed
open
Output IPOS
(FW
> 0: FIN)
Max. 0.5 ms
Max. 0.5 ms
Max. 1 ms.
• Closed: when the target position data is secured.
• Open: when the target position data is lost.
Output IPOS
(FW<
0: CFIN)
(FW =
0: IPOS)

Table of Contents