7.4.2. Customization of Monitor Data
You can output the readout of RS-232C communication monitors to the analog monitors.
You can freely set the offset value and the data range of monitors.
For example, the followings describe the way to monitor the velocity ripple of Motor rotation at
the rotational velocity range of 1 ±0.2 [s
-1
].
1) The monitor TV (Current velocity) monitors the velocity. Type MNTV if you wish to
output the current velocity on the first analog monitor.
:MNTV
MNR10.000;
MNY0.000;
:_
T N M V
SP
ENT
SP
The screen indicates the default. The monitor center is set to 0 [s
-1
] (MNY0.000) and
the output range is set to ± 10 [s
-1
] (MNR10 000). Input the SP for the prompt “:
(colon)”.
An input of TV/MN also set the monitor TV.
2) Set the velocity to 1 [s
-1
] at the monitor center.
MNR10.000;
MNY0.000;
:
MNY1
:_
Y N M 1
#
ENT
3) Set the output range to ± 0.2 [s
-1
] from the monitor center.
MNY0.000;
:MNY1
:
MNR0.2
:_
R N M 0
?
ENT
.
=
2
$
Fig 7-35: How to customize an analog monitor
Motor rotation velocity
+ 5 V
0 V
0.8 [s
-
1
]
1.2 [s
-
1
]
+ 2.5 V
1.0 [s
-
1
]
0.2 [s
-
1
]
Outputs analog data monitored by
the TV (Rotation velocity)
Velocity readout ranges is ± 0.2
[s
-1
]agaisnt the monitor center.
Monitor center (2.5 [V])
corresponds to 1.0 [s
-1
] of
the velecity data.
MNY1.0
MNR0.2
MNTV
TV/MN
o
r
1)
2)
3)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NSK Megatorque PS Series and is the answer not in the manual?

NSK Megatorque PS Series Specifications

General IconGeneral
BrandNSK
ModelMegatorque PS Series
CategoryEngine
LanguageEnglish

Related product manuals