— 8-62 —
8.9.3. Communication with Personal Computer
This section describes the way to back up the parameters of EDC Driver Unit to a personal
computer using Hyper Terminal, which is a bundled program with the Windows
TM
.
The user must provide the communication cable. Refer to “Appendix 6: Wiring of RS-232C
Communication Cable” for wiring of the cable.
For pin arrangement, refer to “2.8.1. CN1: RS-232C Serial Communication Cable Connector”
and the instruction manual of your personal computer.
The pin arrangement for RS-232C connector of EDC Driver Unit is different from that
of DOS/V machines.
An optional communication cable M-C003RS031] is available from NSK Ltd.
For a personal computer that does not provide the COM port, you can use the USB port
instead. In such a case, use an RS-232C and USB gender bender for communication.
One of usable adapter “USB serial cable SRC06-USB” is available from Arvel Co.
8.9.3.1. Setup of Hyper Terminal
1) Start Hyper Terminal
Specify it in the order of [Start] [Programs] [Accessories]
[Communications].
2) The dialog box for “Connection Description” appears.
Declare the name of connection and set an icon, then click [
OK] button.
Set the number of COM port used for “Connection using.”
3) The dialog box for “
COM
Ú
Properties” appears.
Input required data following the table below and click [OK] button.
Table 8-40: specification of RS-232C communication
Item Specification
Bits per second.
9 600
Data bits
8
Parity
None
Stop bits
2
Flow control
Hardware
4) Closing Hyper Terminal.
The dialog box that asks “Do you wand to save session
½½
?” appears.
Click [Yes] to store the session. Use this session for communication with the Driver Unit
afterwards