The example shown below describes how to change the function of output PO7 from the output
NEARA (Target proximity A) to the output ZONEA (Zone A).
1) Specify the output port with the command PO to read out the setting of the parameter
FN.
(The shipping set of the output port PO7 is the output NEARA.)
:
O7
FNNEARA;
GC0;
ST0.0
O P
ENT
7
SP SP
Every input of the SP key displays the parameters GC and ST respectively.
2) Change the output function to the output ZONEA.
GC0;
ST0.0
?
FNZONEA
?_
N F OZ E N
A
ENT
Set the parameters GC and ST in the same way.
3) For the confirmation of the settings, input “?” when the prompt “?” is on the bottom
line.
?
FNZONEA;
GC0;
ST0.0
?
ENT
SP SP
Every input of the SP key displays the parameter FN and GC respectively.
4) Input the ENT
key to quit editing when the prompt “?” is on the last line.
ST0.0
?
:_
ENT