2.Installation
90
Center GUI.
6. Execute the registration with SP5816-206.
7. Check the registration result using SP5816-207.
Check the registration status.
Communication error (proxy enabled)
Check the network condition.
Communication error (proxy disabled)
Check the network condition.
Proxy error (Illegal user name or password)
Check Proxy user name and
password.
See "SP5816-208 Error
Codes" below.
Request number confirmation executing
Processing… Please wait.
Request number error (The applicable device was not registered when
moving the machine was requested.)
Request number error (Data is already registered under this number.)
Check the request number
again.
Request number error (invalid parameter)
Check the request number
again.
8. Exit the SP mode.
SP5816-208 Error Codes
Operation Error,
Incorrect Setting
An Inquiry or registration attempted
without acquiring a request number.
Obtain a Request Number
before inquiry or registration.
Attempted registration without execution
of a confirmation and no previous
registration.
Perform Confirmation before
attempting registration.
Attempted setting with illegal entries for
certification and ID2.
Check ID2 of the machine.
@Remote communication is prohibited.
The device has an Embedded RC gate-
related problem.
Make sure that "Remote Service"
in User Tools is set to "Do not
prohibit".
A confirmation request was made after
the confirmation had been already
completed.
The request number used at registration
was different from the one used at
confirmation.
Check the request number.