4.Service Tables
113
6804D3(H) - Year (BCD)
6804D4(H) - Month (BCD)
6804D5(H) - Day (BCD)
6804D6 (H) - Hour
6804D7 (H) - Minute
6804D8(H) - Second
6804D8 (H) - 00: Monday, 01: Tuesday, 02: Wednesday, /// , 06: Sunday
6804E6(H) - Optional equipment (Read only – Do not change the settings)
Bit 0: Page Memory 0: Not installed, 1: Installed
Bit 1: SAF Memory (4M) 0: Not installed, 1: Installed
Bit 2: SAF Memory 0: Not installed, 1: Installed
Bits 3 to 7; Not used
6804E7(H) - Optional equipment (Read only – Do not change the settings)
Bits 0 to 7: Not used
6804EE(H) - Machine code (Check ram 3)
680500(H) - Start address of G3 table for G3-1
680820 to 68083F(H) - Service station’s fax number (SP3-101)
680840 to 680849(H) - Own fax PABX extension number - Not used
68084A to 680853(H) - Own fax number (PSTN) - Not used
680868 to 680873(H) - The first subscriber number (ISDN G3) - Not used
680874 to 68087F(H) - The second subscriber number (ISDN G3) - Not used
680908(H) - G3-1 Modem ROM version (Read only)
680918(H) - Number of multiple sets print (Read only)
68096E(H) - Not used
68096F(H) - Not used
68098A(H) - Transmission monitor volume 00 - 07(H)
68098B(H) - Reception monitor volume 00 - 07(H)
68098C(H) - On-hook monitor volume 00 - 07(H)
68098D(H) - Dialing monitor volume 00 - 07(H)
68098E(H) - Buzzer volume 00 - 07(H)
68098F(H) - Beeper volume 00 - 07(H)
6809A0(H) - Machine code (Check ram 4)
6809CA(H) - Machine serial number (ASCII)
686D98 to 686D9B(H) - Transmission counter 00000000 - FFFFFFFF(H)
686D9C to 686D9F(H) - Reception counter 00000000 - FFFFFFFF(H)
686E08 to 686E0B(H) - Mail transmission counter 00000000 - FFFFFFFF(H)
686E0C to 686E0F(H) - Mail reception counter 00000000 - FFFFFFFF(H)
6A69EE(H) to 6A6CED(H) - SIP server address (Read only)
6A69EE(H) - Proxy server - Main (Max. 128 characters - ASCII)