CMU Base System CMU
1100.4903.12 6.22 E-10
MMEMory:DATA <FileName> ,<Data> Transfer Data
Parameters
Parameter description Def. value Def. unit
"<FileName>",
<Data>
Name of the destination file
Data to be transferred to the CMU
Parameters for query
Parameter description Def. value Def. unit FW vers.
"<FileName>" Name of the source file – V3.05
Description of command
This command loads <data> from the controller into the file <FileName> stored in the current directory of the
current CMU mass storage device. <data> is in 488.2 block format. The data may be transferred via GPIB bus
or via serial interface.
The query form is MMEMory:DATA? <FileName> with the response being the associated <data> in block for-
mat. In this form the command transfers data from the current CMU mass storage device to the controller.
Instead of the entire data transferred the remote protocol contains a string indicating the length of the block data
in bytes, e.g. <DEF BLOCK (Length = 19)>.
MMEMory:SAVE[:ALL] <FileName> [,<msus>] Save all configurations
Parameters Parameter description Def. value Def. unit FW vers.
"<FileName>",
INTernal | EXTernal
Name of the config. file to be created
Storage device of the config. file
INTernal
V3.10
Command description
This command saves the configuration of all function groups and test modes to a single configuration file. A "?" in
the specified file name will be replaced by current numbers that are automatically incremented, starting with zero.
The auto-increment function overwrites an existing file with a "9" in its file name. For instrument settings that may
be different in manual and remote control (e.g. the repetition mode for many measurements) the manual setting
is saved. This command is CMU-specific.
MMEMory:SAVE:CURRent <FileName> [,<msus>]
Save configurations in current function group and test mode
Parameters
Parameter description Def. value Def. unit FW vers.
"<FileName>",
INTernal | EXTernal
Name of the config. file to be created
Storage device of the config. file
INTernal
V3.10
Command description
This command saves the configuration of the current function group and test mode to a configuration file. A "?" in
the specified file name will be replaced by current numbers that are automatically incremented, starting with zero.
The auto-increment function overwrites an existing file with a "9" in its file name. For instrument settings that may
be different in manual and remote control (e.g. the repetition mode for many measurements) the manual setting
is saved. The command is available in all function groups. This command is CMU-specific.
MMEMory:RECall[:ALL] <FileName> [,<msus>] Recall all configurations
Parameters
Parameter description Def. value Def. unit FW vers.
"<FileName>",
INTernal | EXTernal
Name of the config. file to be recalled
Storage device of the config. file
INTernal
V3.10
Command description
This command recalls the configuration of all function groups and test modes stored in a configuration file. This
command is CMU-specific.