List of Commands CMU
1100.4903.12 6.92 E-10
Command Parameters Remarks Page
CONFigure:IQIF:TXPath BYP | BYIQ | XOIO | IOIO |
IOXO
with query 6.42
Subsystem LEVel (Input Level)
[SENSe:]LEVel:ATTenuation NORMal | LNOise |
LDIStortion
with query 6.27
[SENSe:]LEVel:DEFault ON | OFF with query 6.27
[SENSe:]LEVel:MAXimum –37 dBm to +53 dBm depending on
input and ext.
attenuation set
6.26
[SENSe:]LEVel:MODE MANual | AUTO with query 6.27
[SENSe:]LEVel:REFerence –100 dBm to +53 dBm depending on
input and ext.
attenuation set
6.27
Subsystem NPOWer (narrow-band power)
INITiate:NPOWer – no query 6.59
ABORt:NPOWer – no query 6.59
STOP:NPOWer – no query 6.59
CONTinue:NPOWer – no query 6.59
[SENSe:]NPOWer:BWIDth[:RESolution] 10 Hz to 1 MHz with query 6.61
CONFigure:NPOWer:CONTrol 1 to 1000 |
NONE,CONTinuous |
SINGleshot | 1 ... 10000,
SONerror | NONE,STEP |
NONE
with query 6.60
CONFigure:NPOWer:CONTrol:REPetition CONTinuous | SINGleshot | 1
... 10000, SONerror |
NONE,STEP | NONE
with query 6.61
CONFigure:NPOWer:CONTrol:STATistics 1 to 1000 | NONE with query 6.61
CONFigure:NPOWer:EREPorting SRQ | SOPC | SRSQ | OFF with query 6.59
FETCh:NPOWer:STATus? OFF | RUN | STOP | ERR |
STEP | RDY, 1 to 10000 |
NONE, 1 to 1000 | NONE
query only 6.60
READ[:SCALar]:NPOWer? –30 dBm to +30 dBm query only 6.62
FETCh[:SCALar]:NPOWer? –30 dBm to +30 dBm query only 6.62
SAMPle[:SCALar]:NPOWer? –30 dBm to +30 dBm query only 6.62
Test object POWer (Power)
INITiate:POWer – no query 6.44
ABORt:POWer – no query 6.44
STOP:POWer – no query 6.44
CONTinue:POWer – no query 6.44
CONFigure:SUBarrays:POWer ALL | ARIThmetical | MINimum
| MAXimum |
IVAL,<Start>,<Samples>{,<St
art>,<Samples>}
with query 6.48
READ:ARRay:POWer:AVERage? –128.0 dBm to +48.0 dBm query only 6.49
FETCh:ARRay:POWer:AVERage? –128.0 dBm to +48.0 dBm query only 6.49
SAMPle:ARRay:POWer:AVERage? –128.0 dBm to +48.0 dBm query only 6.49
READ:SUBarrays:POWer:AVERage? –128.0 dBm to +48.0 dBm query only 6.50
FETCh:SUBarrays:POWer:AVERage? –128.0 dBm to +48.0 dBm query only 6.50
SAMPle:SUBarrays:POWer:AVERage? –128.0 dBm to +48.0 dBm query only 6.50
CONFigure:POWer:CONTrol SCALar | ARRay with query 6.45

Table of Contents

Other manuals for Rohde & Schwarz CMU 200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rohde & Schwarz CMU 200 and is the answer not in the manual?

Rohde & Schwarz CMU 200 Specifications

General IconGeneral
BrandRohde & Schwarz
ModelCMU 200
CategoryTest Equipment
LanguageEnglish

Related product manuals