EasyManua.ls Logo

Rohde & Schwarz CMU 200 - Page 359

Rohde & Schwarz CMU 200
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CMU List of Commands
1100.4903.12 6.93 E-10
Command Parameters Remarks Page
CONFigure:POWer:CONTrol:REPetition CONTinuous | SINGleshot | 1
to 10000, NONE,STEP |
NONE
with query 6.45
CONFigure:POWer:EREPorting SRQ | SOPC | SRSQ | OFF with query 6.44
[SENSe:]POWer:FREQuency:BANDwidth[:RESolution] 10 Hz to 1 MHz with query 6.46
[SENSe:]POWer:FREQuency:BWIDth[:RESolution] 10 Hz to 1 MHz with query 6.46
[SENSe:]POWer:FREQuency:CENTer 10 kHz to 2.7 GHz with query 6.46
[SENSe:]POWer:LEVel:RANGe 10.0 dB to 100.0 dB with query 6.46
READ:ARRay:POWer:MAXimum? –128.0 dBm to +48.0 dBm query only 6.49
FETCh:ARRay:POWer:MAXimum? –128.0 dBm to +48.0 dBm query only 6.49
SAMPle:ARRay:POWer:MAXimum? –128.0 dBm to +48.0 dBm query only 6.49
READ:SUBarrays:POWer:MAXimum? –128.0 dBm to +48.0 dBm query only 6.50
FETCh:SUBarrays:POWer:MAXimum? –128.0 dBm to +48.0 dBm query only 6.50
SAMPle:SUBarrays:POWer:MAXimum? –128.0 dBm to +48.0 dBm query only 6.50
READ:ARRay:POWer:MINimum? –128.0 dBm to +48.0 dBm query only 6.49
READ:ARRay:POWer:MINimum? –128.0 dBm to +48.0 dBm query only 6.49
FETCh:ARRay:POWer:MINimum? –128.0 dBm to +48.0 dBm query only 6.49
FETCh:ARRay:POWer:MINimum? –128.0 dBm to +48.0 dBm query only 6.49
SAMPle:ARRay:POWer:MINimum? –128.0 dBm to +48.0 dBm query only 6.49
READ:SUBarrays:POWer:MINimum? –128.0 dBm to +48.0 dBm query only 6.50
READ:SUBarrays:POWer:MINimum? –128.0 dBm to +48.0 dBm query only 6.50
FETCh:SUBarrays:POWer:MINimum? –128.0 dBm to +48.0 dBm query only 6.50
FETCh:SUBarrays:POWer:MINimum? –128.0 dBm to +48.0 dBm query only 6.50
SAMPle:SUBarrays:POWer:MINimum? –128.0 dBm to +48.0 dBm query only 6.50
FETCh:POWer:STATus? OFF | RUN | STOP | ERR |
STEP | RDY, 0 to 10000 |
NONE , 0 to 1000 | NONE
query only 6.44
[SENSe:]POWer:TIME:DELay -1000.0 µs to +1000.0 µs depending on
span and
bandwidth
6.47
[SENSe:]POWer:TIME:SPAN 10 µs to 10 s depending on
bandwidth
6.47
READ:ARRay:POWer[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.49
FETCh:ARRay:POWer[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.49
SAMPle:ARRay:POWer[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.49
READ:SUBarrays:POWer[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.50
FETCh:SUBarrays:POWer[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.50
SAMPle:SUBarrays:POWer[:CURRent]? –128.0 dBm to +48.0 dBm query only 6.50
Subsystem OPTions (options)
SYSTem:OPTions:INFO:CURRent? query only 6.25
Save/Recall of settings
MMEMory:RECall:CURRent <FileName> [,<msus>] no query 6.26
MMEMory:SAVE:CURRent <FileName> [,<msus>] no query 6.25
Partial reset
SYSTem:RESet:CURRent – no query 6.26
Test object RFANalyzer (Power)
INITiate:RFANalyzer – no query 6.30

Table of Contents

Other manuals for Rohde & Schwarz CMU 200

Related product manuals