EasyManuals Logo

Vanderbilt SPC53 Series User Manual

Vanderbilt SPC53 Series
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #149 background imageLoading...
Page #149 background image
Engineer programming via the keypad
16
Isolate
149
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
configuration file name is the same as a file name already
existing in the fast programmer to prevent configuration files
from being overwritten.
DATA TO PANEL: Transfer data to the controller from the
Fast Programmer.
DELETE FILES:
FIRMWARE UPGRADE.
Note: If you downgrade the firmware (i.e. install an older
version of firmware) the system will default all current
configuration settings. Also, when downgrading firmware, it is
important to downgrade the corresponding peripheral
firmware otherwise zones may appear disconnected, opened
or closed.
PERIPHERAL UPGRADE:
LANGUAGE UPGRADE:
SPC PRO/SPC SAFE
To program the following SPC Pro options:
ENABLE ACCESS: Determine if SPC Pro is enabled or
disabled.
ENGINEER ACCESS: Determine if engineer access is
enabled or disabled.
PASSWORD: Edit the existing system password.
IP ENABLE: Enable to connect to the system via IP.
IP PORT: Select which IP Port SPC Pro/SDK will connect
through.
SYSTEM RESTART
To restart the system.
LICENSE
Enter a license number to change the SPC license key. The
system does not log or report a license change.
16.14 Isolate
Zones, system alerts or alerts from X-BUS devices can be manually isolated from
the keypad. Isolating a zone removes that zone from the system until the user de-
isolates it.
To isolate zones, system alerts or alerts from X-BUS devices:
1. Scroll to ISOLATE and press SELECT.
2. Scroll to the desired option in the table below and press SELECT.
ZONE
Select the required zone and toggle the setting from NOT ISOLATED to
ISOLATED.
SYSTEM
Isolate the desired system alert.
XBUS
Isolate the desired alert from EXPANDERS or KEYPADS:
XBUS COMMS LOST
XBUS FUSE FAULT (Expanders only)
X-BUS TAMPER
VIEW ISOLATIONS
To view a list of the isolated zones, system alerts and X-BUS devices alerts.
16.15 Event Log
Recent events on the system are displayed in the EVENT LOG option. Events flash
in one second intervals.
1. Scroll to EVENT LOG and press SELECT.
2. To view an event from a particular date, enter the date with the numeric keys.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC53 Series and is the answer not in the manual?

Vanderbilt SPC53 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC53 Series
CategoryPower Supply
LanguageEnglish

Related product manuals