Engineer programming via the keypad
Installation & Configuration Manual
The type and status of the PSU. (PSU expanders only) Scroll to display the voltage
and current load on the outputs, the battery status. The Mode Link option is also
available, which shows the jumper setting on the panel for the Ah setting. 7Ah and
17Ah are the available options. (This jumper is not present on the 5350 or 6350
models)
If you are using the SPC 5360 or 6350, this menu displays the battery status, and
the status of the fuses on the outputs.
Battery voltage: battery voltage level (PSU expanders only)
State of each zone input associated with an expander as follows:
C: Closed, O: Open, D; Disconnected, S: Short (Expanders with inputs only)
16.6.4.3 Edit Keypads
To edit keypads:
1. Scroll to KEYPADS > EDIT.
2. Press SELECT.
3. Scroll to the device to be edited and press SELECT.
The configuration settings for a standard keypad and comfort keypad are
described in the sections below.
4. Press BACK to exit the menu.
LCD Keypad Settings
Configure the following settings for the keypad.
Enter a unique description to identify the keypad.
Function Keys (in idle state)
Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by
pressing the 2 soft keys together.
If you assign a verification zone to the keypad, when a panic alarm is triggered
by pressing 2 soft keys together or by entering a duress code, audio and video
events are activated.
Select when keypad backlight is on. Options are: - On after key is pressed;
Always on; Always off..
Enable or disable the LED’s on the keypad.
Select if setting state should be indicated in idle mode.
Enable or disable the buzzer on the keypad.
Enable or disable buzzer during exit time on Partset.
Select if the speaker volume for the key presses should be activated.
Select if the keypad should be limited by calendar. See Calendar [➙ 251].
Select if keypad should be limited by a mapping gate.
Select if keypad should be limited by a keyswitch.
Tick this box to disable the keys on the keypad during the entry time when a
PACE is configured on the keypad.
Select the secured area where the keypad is located.
Select which areas can be controlled through keypad.