Engineer programming via the browser
Configuring Communications
Installation & Configuration Manual
Any additional information for the RCT.
17.10.2.4 Configuring an SPC Connect ATS
The Add SPC Connect ATS functionality opens a communication between the
panel (SPT) and the SPC Connect server (RCT), www.spcconnect.com. Using the
generated SPC Connect ATS Registration ID, a panel user can register a user
account and panel with the SPC Connect website to access their panel remotely.
1. To configure an SPC Connect ATS, go to Communications - FlexC - FlexC
ATS.
2. In the ATS Configuration screen, click Add SPC Connect to open a
communication path with the SPC Connect server.
An SPC Connect ATS is added to the Event Sequence Table with the following
attributes:
SPC Connect ATS Registration ID
Default ATP over Ethernet. For information on ATP fields, see Add ATP to
FlexC RCT [➙ 278]
Default Events Profile for SPC Connect
Default Commands Profile for SPC Connect
Default RCT URL is www.spcconnect.com
The SPT Account Code for the ATP is populated.
Make a note of the SPC Connect ATS Registration ID and provide this to the
customer along with the
SPC Connect User Guide
.
17.10.2.5 Exporting and Importing an ATS
ATS files have a .cxml extension. You must create the ATS in the SPC browser
and export it before you can import it to a system.
1. To export an ATS, go to Communications - FlexC - FlexC ATS.
2. In the Configured ATS table, locate the ATS to export and click the Export ATS
button (green arrow).