16
Engineer programming via the keypad
Areas
116
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Timer
Description
Default
General Settings
RF Output Time
RF OUTPUT
The time that the RF output will remain active on the system.
(0 999 seconds)
0 sec.
Time Sync Limit
TIME SYNC LIMIT
Time limit within which no event will be reported.
(0 999 secs) Time synchronization only takes place if
system time and update time are outside this limit.
0 sec.
Link Timeout
LINK TIMEOUT
Timeout for Ethernet link fault (0 = Disabled) ( 0 - 250 )
0 secs
Camera Offline
CAMERA OFFLINE
Time for camera to go offline ( 10 - 9999 )
10 secs
Tech. delay
TECH. DELAY
Number of seconds to delay triggering of tech. zones with
tech. delay attribute. (0 9999 seconds)
0 sec.
Frequent
FREQUENT
This attribute only applies to Remote Maintenance. The
number of hours a zone must open within if the zone is
programmed with the Frequent use attribute. (1 9999 hours)
336 hours (2
weeks)
Duress silent
Time when duress will remain silent and not restorable from
keypad (0 - 999).
0 Minutes
Holdup/panic silent
Number of minutes that a holdup/panic will remain silent and
cannot be restored from the keypad (0 - 999).
0 Minutes
Default times are dependent upon the Engineer configuration. The default times
denoted may or may not be allowable and is dependent on the configuration by
the engineer
16.4 Areas
1. Scroll to AREAS and press SELECT.
2. Scroll to the desired programming option:
ADD
For Domestic and Commercial Mode, the area type defaults to Standard.
In Financial Mode, select area type STANDARD, ATM, VAULT or
ADVANCED.
Enter the name of the area and the preferred entry/exit time.
EDIT
Edit the following settings:
DESCRIPTION
ENTRY EXIT
ENTRY TIMER
EXIT TIMER
NO EXIT TIMER
FOB ENTRY ACTIVE
PARTSET A/B
ENABLED/DISABLED
TIMED
ACCESS TO E/EXIT
E/EXIT TO ALARM
LOCAL
NO BELLS
!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC53 Series and is the answer not in the manual?

Vanderbilt SPC53 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC53 Series
CategoryPower Supply
LanguageEnglish

Related product manuals