Engineer programming via the keypad
Installation & Configuration Manual
The time that the RF output will remain active on the system.
(0 – 999 seconds)
Time limit within which no event will be reported.
(0 – 999 secs) Time synchronization only takes place if
system time and update time are outside this limit.
Timeout for Ethernet link fault (0 = Disabled) ( 0 - 250 )
Time for camera to go offline ( 10 - 9999 )
Number of seconds to delay triggering of tech. zones with
tech. delay attribute. (0 – 9999 seconds)
This attribute only applies to Remote Maintenance. The
number of hours a zone must open within if the zone is
programmed with the Frequent use attribute. (1 – 9999 hours)
Time when duress will remain silent and not restorable from
keypad (0 - 999).
Number of minutes that a holdup/panic will remain silent and
cannot be restored from the keypad (0 - 999).
Default times are dependent upon the Engineer configuration. The default times
denoted may or may not be allowable and is dependent on the configuration by
the engineer
16.4 Areas
1. Scroll to AREAS and press SELECT.
2. Scroll to the desired programming option:
For Domestic and Commercial Mode, the area type defaults to Standard.
In Financial Mode, select area type STANDARD, ATM, VAULT or
ADVANCED.
Enter the name of the area and the preferred entry/exit time.
Edit the following settings:
DESCRIPTION
ENTRY EXIT
– ENTRY TIMER
– EXIT TIMER
– NO EXIT TIMER
– FOB ENTRY ACTIVE
PARTSET A/B
– ENABLED/DISABLED
– TIMED
– ACCESS TO E/EXIT
– E/EXIT TO ALARM
– LOCAL
– NO BELLS