Engineer programming via the browser
Installation & Configuration Manual
- Block remote isolates
- Block remote inhibits
- No external bell if internal set
- Delay reporting if entry active
- Confirmed alarm cancels delay
Confirmed
Alarms System
Alerts
Select which system alerts cause a confirmed alarms
when at least one alarm is active, and which system
alerts cause the panel to enter the tentative state.
Enter the first hold-up keyword to send to the CMS in a
Holdup Information (HD) event.
Enter the second hold-up keyword to send to the CMS in
a Holdup Information (HD) event.
Enter the first site phone number to send to the CMS in a
Holdup Information (HD) event.
Enter the second site phone number to send to the CMS
in a Holdup Information (HD) event.
See also
Adding / Editing an area [➙ 238]
17.9.4.2 Timers
This window gives an overview about identified timer defaults and their description.
These settings, which vary depending on the defined Security Grade of the
system, should only be programmed by an authorised installation engineer.
Changing settings could render the SPC system noncompliant with security
standards. Setting the Security Grade back to EN 50131 Grade 2 or EN 50131
Grade 3 overwrites any changes made on this page.
1. Select Configuration > System > SystemTimers.
The following window will be displayed.
2. Configure the fields as described in the table below.
Timers
Designation of the functions in the following order:
1
st
row: Web/SPC Pro
2
nd
row: Keypad
Duration that internal sounders will sound when alarm is
activated. (1 – 15 minutes: 0 = never))
External Bells
EXT BELL TIME
Duration that external sounders will sound when alarm is
activated. (1 – 15 minutes; 0 = never)