Door Expander
9
71
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
9 Door Expander
The two door expander can handle up to two doors and two card readers.
Configuration of the operation mode is done via the two door I/Os. Each of the two
door I/Os is responsible for the functionality of two inputs and one output of the
door controller. A specific door number can be assigned to a door I/O, which gives
the inputs and output predefined functionality. If no door number is assigned to
neither of the door I/Os (option “Zones” is selected), the inputs and outputs of the
door controller can be used like inputs and outputs on the control panel. Thus, no
access functionality is available on this two door controller.
If a door number is assigned only to the first door I/O of the two door controller, the
first reader is used as entry reader for this door. If a second reader is available, it is
used as exit reader for the configured door. Two inputs and one output have
predefined functionality and two inputs and one output can be configured by the
user. Additionally, the door position sensor input of the first door can be used as
intrusion zone but only with limited functionality.
If a door number is assigned to each of the two door I/Os, the two doors are
handled independently. The first card reader is used as entry reader for the first
door and the second card reader is used as entry reader for the second door. All
inputs and outputs have predefined functionality. The door position sensor inputs of
the two doors can additionally be used as intrusion zones but only with limited
functionality.
Refer to the Appendix [➙ 354] for details of currently supported card readers and
card formats.
Each free zone number can be assigned to the zones. But the assignment is not
fixed. If number 9 was assigned to a zone, the zone and an input expander with
the address 1 is connected to the X-Bus (which is using the zone numbers 9-
16).The assigned zone from the two door controller will be moved to the next free
zone number. Configuration will be adapted accordingly.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC53 Series and is the answer not in the manual?

Vanderbilt SPC53 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC53 Series
CategoryPower Supply
LanguageEnglish

Related product manuals