19 Intruder alarm functionality
The SPC system can accommodate 3 distinct modes of intruder alarm operation,
Financial, Commercial or Domestic mode, all of which support multiple areas.
Each area in turn can support 4 different alarm modes. Commercial and Financial
mode present more programmable alarm types than Domestic mode. The default
zone name and type settings for each mode is listed in page [âž™ 336].
19.1 Financial mode operation
Financial mode is suitable banking and financial businesses that have special
secure areas such as vaults and ATMs.
Each area defined on the system supports the alarm modes listed below.
Alarm Mode
Description
UNSET
Area is disarmed, only alarm zones classified as 24Hour will activate the alarm.
PARTSET A
This mode provides perimeter protection to a building while allowing free
movement through the exit and access areas.
Zones that have been classified as EXCLUDE A remain unprotected in this mode.
By default there is no exit time (the system instantly sets on selection of this
mode). An exit timer can be applied to this mode by enabling the Partset A Timed
variable.
PARTSET B
This setting mode applies protection to all zones except those that have been
classified as EXCLUDE B.
By default there is no exit time (the system instantly sets on selection of this
mode). An exit timer can be applied to this mode by enabling the Partset B Timed
variable.
FULL SET
Area is fully armed; opening of entry/exit zones starts the entry timer. If the alarm
is not unset before entry timer expires, the alarm is activated.
19.2 Commercial mode operation
Commercial mode is suitable for business installations with multiple areas and a
large number of alarm zones. Each area defined on the system supports the alarm
modes listed below.
Alarm Mode
Description
UNSET
Area is disarmed, only alarm zones classified as 24Hour will activate the alarm.
PARTSET A
This mode provides perimeter protection to a building while allowing free
movement through the exit and access areas.
Zones that have been classified as EXCLUDE A remain unprotected in this mode.
By default there is no exit time (the system instantly sets on selection of this
mode). An exit timer can be applied to this mode by enabling the Partset A Timed
variable.
PARTSET B
This setting mode applies protection to all zones except those that have been
classified as EXCLUDE B.
By default there is no exit time (the system instantly sets on selection of this
mode). An exit timer can be applied to this mode by enabling the Partset B Timed
variable.
FULL SET
Area is fully armed; opening of entry/exit zones starts the entry timer. If the alarm
is not unset before entry timer expires, the alarm is activated.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC53 Series and is the answer not in the manual?

Vanderbilt SPC53 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC53 Series
CategoryPower Supply
LanguageEnglish

Related product manuals