Engineer programming via the keypad
Installation & Configuration Manual
4. If testing the controller outputs, scroll to the preferred output and press
SELECT. If testing the expander outputs, select the expander and then the
output.
The keypad display indicates the current state of the output on the top line.
5. Toggle the output state ON/OFF.
6. Check that the device connected to the selected output changes state
accordingly.
16.12.5 Soak Test
A Soak Test provides a method of putting selected zones on test. Zones on soak
test do not cause any alarms but are recorded in the event log. Zones on soak test
will remain on soak test until the soak test timer expires as in the timers default (14
days).
To perform a soak test:
1. Scroll to SOAK TEST and press SELECT.
2. Toggle between ENABLE SOAK and CANCEL SOAK for preferred option.
3. Scroll to preferred zone and press SELECT.
A message confirming that the zone is in soak is displayed.
All zone types can be included in a Soak test.
16.12.6 Audible Options
The audible options are applied as indicators within a walk test.
To set the audible options:
1. Scroll to AUDIBLE OPTIONS.
2. Press SELECT.
3. Scroll to one of the following options: ALL, INT BELL, EXT BELL, KEYPAD
4. Press SAVE.
5. Press BACK to exit.
16.12.7 Visual Indicators
This test is used to test all the pixels on the LCD Keypad and all the pixels and
LED indicators on the Comfort Keypad, Indicator module and Keyswitch.
To test a keypad:
1. Scroll to VISUAL IND.
2. Press SELECT.
3. Press ENABLE.
On the LCD keypad, two rows of continuously changing characters are displayed.
On the Comfort keypad, all the LED indicators are lit and all screen pixels are
displayed.
1. Press BACK to disable the test.