Engineer programming via the browser
Installation & Configuration Manual
17 Engineer programming via the browser
Engineer programming options on the SPC panel can be accessed via any
standard web browser on a PC and is PIN protected.
You can access Engineer Programming via the browser by entering the default
Engineer PIN (1111). For more details, see Engineering PINs [âž™ 102].
This web server provides access to the complete set of programming features used
to install and configure the SPC system.
This programming option should only be provided to authorized installers of the
SPC system.
Engineer Programming features on the SPC are divided into the following
categories:
Soft Engineer Features
These features can be programmed without requiring the alarm system to be
deactivated; they are accessible directly upon entering Engineer mode.
Full Engineer Features
These features require the alarm system to be deactivated before programming
can commence; these features are accessible under the Full Engineer menu.
If ‘Engineer Exit’ option is enabled in System Options, the engineer is allowed
leave Full Engineer mode with alerts active but must acknowledge all alerts listed
on the keypad or in the browser before switching from Full Engineer mode to Soft
Engineer mode.
The web server on SPC controller can be accessed using either the Ethernet or
USB interface.
If programming with a browser interface, click Save when making changes.
Click Refresh to view the current programming values on a web page.
17.1 System Information
Click the ? icon to view the Help menu which provides up-to-date information about
the panel and the functionality that is currently licensed on the system.
17.2 Ethernet interface