Engineer programming via the browser
Installation & Configuration Manual
See also
Configuring system latch and auto set outputs [➙ 202]
17.9.1.3 Configuring system latch and auto set outputs
Under Policy, click on the Edit button for the Output Configuration option in
System Options.
The following screen is displayed:
Select the condition under which the latch output is activated:
Output turns on at the end of Exit time and off at the beginning
of Entry time.
Output turns on if any fire exit zones are active.
Output turns on if any user unsets system momentary
Output turns on if an alarm is reset momentary.
Output turns on during a setting procedure if glass break/smoke
open and not in alarm.
Output turns on when an engineer exits from Engineer mode
momentary.
Output turns on when valid user PIN entered on keypad and fire
zone is active
Select the behavior of the output.
Output will remain on if auto set is active.
Output will follow keypad operation.