23.24 ATS Category Timings
This table describes the EN50136-1 ATS Category Timings laid down in the
standard and how the FlexC implementation meets these standards under the
categories SP1-SP6, DP1-DP4.
EN50136-1 ATS Category Timing
Requirements
FlexC Implementation of ATS
Category Timing Requirements
ATS
Catego
ry
Default
Interfac
es
Event
Timeo
ut
Primar
y
Polling
Timeo
ut
Backup
ATP
Polling
Timeout
(Primary
OK)
Backup
ATP
Polling
Timeout
(Primary
Down)
Event
Timeo
ut
Primar
y
Polling
Timeo
ut
Backup
ATP
Polling
Timeout
(Primary
OK)
Backup
ATP
Polling
Timeout
(Primary
Down)
SP1
Cat 1
[Ethern
et]
8 min
32
days
-
-
2 min
30
days
-
-
SP2
Cat 2
[Ethern
et]
2 min
25 hr
-
-
2 min
24 hr
-
-
SP3
Cat 3
[Ethern
et]
60 s
30 min
-
-
60 s
30 min
-
-
SP4
Cat 4
[Ethern
et]
60 s
3 min
-
-
60 s
3 min
-
-
SP5
Cat 5
[Ethern
et]
30 s
90 s
-
-
30 s
90 s
-
-
SP6
Cat 6
[Ethern
et]
30 s
20 s
-
-
30 s
20 s
-
-
DP1
Cat 2
[Ethern
et]
Cat 2
[Modem
]
2 min
25 hr
50 hr
25 hr
2 min
24 hr
24 hr 30
min
24 hr 10
min
DP2
Cat 3
[Ethern
et]
Cat 3
[Modem
]
60 s
30 min
25 hr
30 min
60 s
30 min
24 hr 30
min
30 min
DP3
Cat 4
[Ethern
et]
Cat 4
[Modem
]
60 s
3 min
25 hr
3 min
60 s
3 min
24 hr 30
min
3 min
DP4
Cat 5
[Ethern
et]
Cat 5
[Modem
]
30 s
90 s
5 hr
90 s
30 s
90 s
4 hr 10
min
90 s