EasyManuals Logo

Vanderbilt SPC53 Series User Manual

Vanderbilt SPC53 Series
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #362 background imageLoading...
Page #362 background image
23
Appendix
ATS Category Timings
362
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
23.24 ATS Category Timings
This table describes the EN50136-1 ATS Category Timings laid down in the
standard and how the FlexC implementation meets these standards under the
categories SP1-SP6, DP1-DP4.
EN50136-1 ATS Category Timing
Requirements
FlexC Implementation of ATS
Category Timing Requirements
ATS
Catego
ry
Default
Interfac
es
Event
Timeo
ut
Primar
y
Polling
Timeo
ut
Backup
ATP
Polling
Timeout
(Primary
OK)
Backup
ATP
Polling
Timeout
(Primary
Down)
Event
Timeo
ut
Primar
y
Polling
Timeo
ut
Backup
ATP
Polling
Timeout
(Primary
OK)
Backup
ATP
Polling
Timeout
(Primary
Down)
SP1
Cat 1
[Ethern
et]
8 min
32
days
-
-
2 min
30
days
-
-
SP2
Cat 2
[Ethern
et]
2 min
25 hr
-
-
2 min
24 hr
-
-
SP3
Cat 3
[Ethern
et]
60 s
30 min
-
-
60 s
30 min
-
-
SP4
Cat 4
[Ethern
et]
60 s
3 min
-
-
60 s
3 min
-
-
SP5
Cat 5
[Ethern
et]
30 s
90 s
-
-
30 s
90 s
-
-
SP6
Cat 6
[Ethern
et]
30 s
20 s
-
-
30 s
20 s
-
-
DP1
Cat 2
[Ethern
et]
Cat 2
[Modem
]
2 min
25 hr
50 hr
25 hr
2 min
24 hr
24 hr 30
min
24 hr 10
min
DP2
Cat 3
[Ethern
et]
Cat 3
[Modem
]
60 s
30 min
25 hr
30 min
60 s
30 min
24 hr 30
min
30 min
DP3
Cat 4
[Ethern
et]
Cat 4
[Modem
]
60 s
3 min
25 hr
3 min
60 s
3 min
24 hr 30
min
3 min
DP4
Cat 5
[Ethern
et]
Cat 5
[Modem
]
30 s
90 s
5 hr
90 s
30 s
90 s
4 hr 10
min
90 s

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC53 Series and is the answer not in the manual?

Vanderbilt SPC53 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC53 Series
CategoryPower Supply
LanguageEnglish

Related product manuals