Engineer programming via the browser
Installation & Configuration Manual
Enable this feature to ensure that the engineer can only
access the system if the user allows it.
If disabled, ENABLE ENGINEER menu option on keypad
is not available.
Note: Only available if Security Grade is ‘Unrestricted’.
For Grade 2 / 3, user control of engineer access to
system is always available.
Enable this feature to ensure that the engineer can only
access the system if the user allows it.
If disabled, ENABLE MANUFACTURER menu option on
keypad is not available.
Note: Only available if Security Grade is ‘Unrestricted’.
For Grade 2 / 3, user control of engineer access to
system is always available if user type is ‘Manager’.
Select one of the following options:
PIN Code Only: This is a valid user code. See page.
Caller ID Only: This is the phone number (including
three-digit country prefix code) as configured for user
SMS control. SMS control will only be available for
configuration by the user when this option is
selected.
PIN and Caller ID
SMS PIN Code Only This is a valid PIN code
configured for the user which is different from the
user’s login code. SMS controls will only be available
for configuration by the user when this option is
selected.
SMS PIN Code & Caller ID.
Configure engineer login and tamper reporting behavior
for system.
Display system timing policy.
Click on the Edit button to configure latch and autoset
output settings [➙ 202].
This programming option allows you to restrict the user
and engineer’s ability to restore, Isolate and inhibit alerts.
The manner in which the system reacts to alerts can also
be programmed.
Select whether particular zone alarms can be restored,
inhibited or isolated by the user and engineer.
Select whether particular zone tampers can be restored,
inhibited or isolated by the user and engineer.
Select events to be displayed on keypads in both Set and
Unset modes.
Select which LEDs will be displayed on keypads in both
Set and Unset modes.
Select options to manage remote control of the system
and alarm and bell settings from the following:
- No confirmed alarms if internally set