Chapter 18 List of Parameters/Modbus Coil/Register Numbers
18-2-21
Code
Name
Data range
Initial
value
Set
value
Change
during
running
Modbus communication
Page
Register No.
Data Range
Resolution
C055
Over/ Under-
torque level
(Forward drive)
0 to 200 (%)
100
✓
143Bh
0 to 200
1
9-6-4
C056
Over/ Under-
torque level
(Reverse
regenerative)
0 to 200 (%)
100
✓
143Ch
0 to 200
1
C057
Over/ Under-
torque level
(Reverse drive)
0 to 200 (%)
100
✓
143Dh
0 to 200
1
C058
Over/ Under-
torque level
(Forward
regenerative)
0 to 200 (%)
100
✓
143Eh
0 to 200
1
C059
Over/ Under-
torque output
signal mode
selection
00: Enable during running
01: Enable only during
constant speed
01
✓
143Fh
0 to 1
-
C061
Electronic
thermal warning
level (Motor)
0 to 100 (%)
90
✓
1441h
0 to 100
1
9-11-5
C063
Zero speed
detection level
0.00 to 100.00 (Hz)
0.00
✓
1443h
0 to 10000
0.01
9-13-4
C064
Cooling fin
overheat warning
level
0 to 110 (°C)
100
✓
1444h
0 to 110
1
9-11-6
C071
RS485
communication
baud rate
selection
03: 2400bps
04: 4800bps
05: 9600bps
06: 19.2kbps
07: 38.4kbps
08: 57.6kbps
09: 76.8kbps
10: 115.2kbps
05
✓
144Bh
3 to 10
-
11-1-1
C072
RS485
communication
node address
1 to 247
1
✓
144Ch
1 to 247
1
C074
RS485
communication
parity selection
00: No parity
01: Even parity
02: Odd parity
00
✓
144Eh
0 to 2
-
C075
RS485
communication
stop bit selection
01: 1bit
02: 2bit
01
✓
144Fh
1 to 2
-
C076
RS485
communication
error selection
00: Trip
01: Trip after deceleration
stop
02: Ignore
03: Free run stop
04: Deceleration stop
02
✓
1450h
0 to 4
-
C077
RS485
communication
timeout
0.00: Disabled
0.01 to 99.99 (s)
0.00
✓
1451h
0 to 9999
0.01
C078
RS485
communication
wait time
0 to 1000 (ms)
0
✓
1452h
0 to 1000
1
C081
[Ai1] Input gain
adjustment
0.0 to 200.0 (%)
100
✓
1455h
0 to 2000
0.1
9-15-4
C082
[Ai2] Input gain
adjustment
0.0 to 200.0 (%)
100
✓
1456h
0 to 2000
0.1
C085
Thermistor gain
adjustment
0.0 to 200.0 (%)
100
✓
1459h
0 to 2000
0.1
9-10-7
C091
Debug mode
selection
For factory adjustment
(Do not change from 00)
00
-
-
-
-
-
C096
RS485
communication
mode selection
01: Modbus-RTU
02: EzCOM
03: EzCOM Administrator
00
✓
1464h
0 to 2
-
11-1-1
11-4-2
C098
EzCOM start
node No.
1 to 8
1
×
1466h
1 to 8
1
11-4-2
C099
EzCOM end node
No.
1 to 8
1
×
1467h
1 to 8
1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi WJ C1 Series and is the answer not in the manual?

Hitachi WJ C1 Series Specifications

General IconGeneral
BrandHitachi
ModelWJ C1 Series
CategoryInverter
LanguageEnglish

Related product manuals