LCD Operation D2 Series Servo Drive User Manual
7-24 HIWIN MIKROSYSTEM CORP.
Parameter Definition Unit Default Max. Min.
354
#
X_latch_err_un
derv
Latch the error massage of “under voltage”
0: Disable
- 0 1 0
355
#
X_mult_emu_in
d
Emulated index output in every revolution
0: Disable
- 0 1 0
357
#
AT.mode
Mode setting for the second generation of
Auto tune
1: Standard
- 1 2 1
358
#
AT.stiff
Stiffness setting for the second generation
of Auto tune
1: Soft
2: Normal
- 2 3 1
359
#
X_Mbus_Baud
RateIndex
Baud rate for the Modbus communication
0: 9,600 (default)
1: 2,400
2: 4,800
3: 9,600
4: 14,400
5: 19,200
bps 0 6 0
360
Drive station number (for Modbus)
- 0 247 0
361
#
X_Mbus_SetPa
rity
Check setting for the Modbus parity
0: 8 data, Even parity, 1 stop bit
1: 8 data, Odd parity, 1 stop bit
2: 8 data, None parity, 2 stop bit
3: 8 data, Even parity, 1 stop bit
4: 7 data, Odd parity, 1 stop bit
5: 7 data, None parity, 2 stop bit
6: 7 data, Even parity, 1 stop bit
- 0 6 0
362
X_Mbus_T15
Maximum time interval for the Modbus
RTU character
ms 3 2
31
-1 1
363
X_Mbus_T35
Minimum time interval for the Modbus RTU
frame
ms 4 2
31
-1 1
364
X_TMO_Scale Output scale of analog output 1
% 100 300 1
Output offset of analog output 1
Output scale of analog output 2
Output offset of analog output 2
368
PDL parameter which can be saved in
Flash
- 0 3.4X10
38
-3.4X10
38
369
PDL parameter which can be saved in
Flash
- 0 3.4X10
38
-3.4X10
38
370
PDL parameter which can be saved in
Flash
- 0 3.4X10
38
-3.4X10
38
371
PDL parameter which can be saved in
Flash
- 0 3.4X10
38
-3.4X10
38
372
PDL parameter which can be saved in
Flash
- 0 3.4X10
38
-3.4X10
38
373
PDL parameter which can be saved in
Flash
- 0 2
31
-1 -(2
31
- 1)