Replacing the SAN Volume Controller 2145-CF8 operator-information panel
assembly
You can replace the operator-information panel on a SAN Volume Controller 2145-CF8.
DANGER
Multiple power cords. The product might be equipped with multiple power cords. To remove all
hazardous voltages, disconnect all power cords.
This service action assumes that:
v The node is turned off. If you must turn off the node, ensure that its data is mirrored and
synchronized, and that there are no dependent volumes, as described in MAP 5350 in the IBM System
Storage SAN Volume Controller 2145 Troubleshooting Guide .
v The power cables are disconnected.
v The top cover is removed.
Perform the following steps to replace the operator-information panel:
1. Read the safety information to which “Preparing to remove and replace parts” on page 20 refers.
2. From the front of the node, slide the operator-information panel into the node until it clicks into
place.
3. Inside the node, connect the cable to the rear of the operator information panel assembly.
1 Operator-information panel
2 Release tab
The following illustration shows the cable routing for the operator-information panel:
Note: The operation information panel cable should go in above the Video/USB cable in the node.
1
2
Figure 216. Replacing the SAN Volume Controller 2145-CF8 operator-information panel
Chapter 2. Removing and replacing parts 197

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM SAN Volume Controller and is the answer not in the manual?

IBM SAN Volume Controller Specifications

General IconGeneral
Product NameIBM SAN Volume Controller
CategoryStorage
Storage VirtualizationYes
RAID SupportYes
Compression SupportYes
Encryption SupportYes
Host InterfaceFibre Channel, iSCSI, FCoE, SAS
RAID LevelsRAID 0, 1, 5, 6, 10
Maximum Cache Per System2TB
Supported Drive TypesSSD
High AvailabilityYes

Related product manuals