Page #34 background image
Table 6. FRUs that are exchanged within SAN Volume Controller 2145-8A4 service procedures (continued)
Assembly index Part number Units Description
- 31P1177 1 Power cable assembly
(SAN Volume Controller to
the 2145 UPS-1U).
The SAN Volume
Controller 2145-8A4 does
not work with previous
versions of the power cable
assembly. The correct
power cable assembly is
indicated by the red tape
that is used to bind the
cables together.
- 12R9914 1 External fibre-channel
cable, LC–LC, 5.0 m (16.4
ft)
- 12R9915 1 External fibre-channel
cable, LC–LC, 25.0 m (82 ft)
- 59P4739 1 Alcohol wipe
- 41Y9292 1 Thermal grease
Table 7. FRUs that are not exchanged within SAN Volume Controller 2145-8A4 service procedures
Assembly index Part number Quantity Description
- 32P9107 1 Support rail kit
- 31P1171 1 Cable retention bracket
- 43W5119 1 Chassis
1 42C1284 1 Top cover
9 42C1286 1 Drive cage
11 43W5115 1 Front bezel
14 39M6296 1 Air baffle
16 43W5117 1 Heat-sink assembly
retention module
17 43W5116 1 Heat-sink assembly
- 42C1282 1 3.5 in. SATA service label
- 43W5113 1 Service label
- 43W5114 1 CRU/FRU label
- 39M4351 2 Bracket ear
SAN Volume Controller 2145-8G4 parts
You might need to replace a SAN Volume Controller 2145-8G4 field replaceable unit (FRU).
Figure 3 on page 9 shows how the different parts of the SAN Volume Controller 2145-8G4 are assembled.
8 IBM SAN Volume Controller Hardware Maintenance Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM SAN Volume Controller and is the answer not in the manual?

IBM SAN Volume Controller Specifications

General IconGeneral
Product NameIBM SAN Volume Controller
CategoryStorage
Storage VirtualizationYes
RAID SupportYes
Compression SupportYes
Encryption SupportYes
Host InterfaceFibre Channel, iSCSI, FCoE, SAS
RAID LevelsRAID 0, 1, 5, 6, 10
Maximum Cache Per System2TB
Supported Drive TypesSSD
High AvailabilityYes

Related product manuals