The redundant ac-power switch FRU assembly includes the redundant ac-power switch and the input
power cables. They should all be replaced together.
These instructions assume that a redundant ac-power switch has been removed and the one or two nodes
that were connected to it are powered off.
To replace a redundant ac-power switch, complete the following steps:
1. Attach each of the two mounting plates to the redundant ac-power switch using three M3 Torx T8
head screws. Position the mounting face, as shown in Figure 293, on the side of the redundant
ac-power switch that contains the output power sockets.
2. Using the labels provided, label each end of the two redundant ac-power switch input power cables.
Unless the configuration is changing, the labels are the same as those on the cables removed with
the old redundant ac-power switch. Label the rack power distribution end “Power source <name>,
outlet <id> to redundant ac-power switch <location> <MAIN | BACKUP> input. For example: “Power
source D2, outlet 4 to redundant ac-power switch pos 7 MAIN input”.
3. Label the redundant ac-power switch end“ redundant ac-power switch <location> <MAIN | BACKUP>
input from Power source <name>, outlet <id>”.
4. Connect the input power cables to the redundant ac-power switch. You want to connect the cables
now, because it is difficult to access the input power sockets on the redundant ac-power switch
when it is installed in a rack.
5. Connect the main input power cable to the redundant ac-power switch.
6. Connect the backup input power cable to the redundant ac-power switch.
7. Secure both the redundant ac-power switch input cables, as shown in Figure 294 on page 270, using
the clips of the redundant ac-power switch.
svc00294
Figure 293. Attaching the mounting plates
Chapter 2. Removing and replacing parts 269

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM SAN Volume Controller and is the answer not in the manual?

IBM SAN Volume Controller Specifications

General IconGeneral
Product NameIBM SAN Volume Controller
CategoryStorage
Storage VirtualizationYes
RAID SupportYes
Compression SupportYes
Encryption SupportYes
Host InterfaceFibre Channel, iSCSI, FCoE, SAS
RAID LevelsRAID 0, 1, 5, 6, 10
Maximum Cache Per System2TB
Supported Drive TypesSSD
High AvailabilityYes

Related product manuals