TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Nugget
Co de 39
6-8
Problems While Operating the Terminal (continued)
Problem Solution
You see both these symptoms:
The Battery icon remains on solid.
The terminal beeps once every 15
seconds.
The main battery pack charge is low. You have a few minutes of
power left. Replace the main battery pack with a spare charged battery
pack, or charge the battery pack.
You see both these symptoms:
The Battery icon blinks.
The terminal beeps once every 15
seconds.
The main battery pack charge and the backup battery charge are both
low. Immediately turn off the terminal.
Replace the main battery pack with a spare charged battery pack. Let
the main battery pack charge the backup battery. The backup battery
will be fully charged in approximately 18 hours. If you have been
using the terminal in a cold temperature environment, move the
terminal to a warmer environment to charge the backup battery.
If the backup battery will not charge, you may need to replace it. For
help, contact your local Intermec service representative.
Problems While Configuring the Terminal
You can configure the terminal by using the TRAKKER Antares 2400 Menu System or
by scanning configuration commands. If you have problems configuring the terminal,
check these possible problems and solutions.
Problem Solution
On the T2425, you configure the RF security
ID and the changes do not appear to be
saved.
You can only set the RF security ID with the 2.4 GHz RF network
enabled. The Network Activate configuration command must be
configured to 2.4 GHz RF network before you can save any changes to
the RF security ID command.
On a T2425, you see this error message when
exiting the Configuration Menu:
Network configuration error.
Network is enabled. Terminal IP
address or Controller (Host) IP
address set to an invalid
address of 0.x.x.x or
127.x.x.x. Configuration was
not updated.
The 2.4 GHz RF network is enabled and there is a problem with the
network configuration. You need to change the terminal IP address
and/or the controller IP address (host IP address for a TCP/IP
network). Choose Primary Network from the Communications Menu.
The terminal IP address or the controller/host IP address is set to
0.x.x.x or 127.x.x.x. These are invalid addresses. Set a valid IP
address for the terminal and controller or host.
For help, see “Using RF Communications on the T2425” in Chapter 4.
If you cannot fix the addressing problem, check with your network
administrator to get the IP address assigned to the terminal and the
controller or host.