TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Co de 39
Nugget
9-40
Controller Connect Check Receive Timer
Purpose: During periods of inactivity on the T2425, the terminal still sends messages to the
DCS 300 to check the RF connection. If no message is received within the time set for the
Controller Connect Check Receive Timer, the terminal is no longer connected to the
DCS 300 and the Connect icon blinks. The timer countdown resets each time a valid
message is received.
Power Management Tip: Intermec strongly recommends that you use the optimum
setting of 60 seconds to preserve the main battery pack’s power.
Syntax: NPdata
Acceptable values for data are any number from 1 to 3600 seconds (60 minutes).
Default: 60 seconds
Scan: To set the default controller connect check receive timer, scan this bar code:
Default Controller Connect Check Receive Timer
*$+NP60*
*$+NP60*
Or: To set the controller connect check receive timer:
1. Scan this bar code:
Enter Accumulate Mode / Set Controller Connect Check Receive Timer
*+/$+NP*
*+/$+NP*
2. Scan a numeric value for data from these bar codes:
*0* *1*
*0* *1*
*2* *3*
*2* *3*
*4* *5*
*4* *5*
*6* *7*
*6* *7*