TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Co de 39
Nugget
9-82
Plessey
Purpose: Enables or disables decoding of Plessey symbology. Plessey code is pulse-width
modulated like most other bar codes. It includes a start character, data characters, an
eight-bit cyclic check digit, a termination bar, and usually a reverse start character. The
code is continuous and not self-checking. You need to configure two parameters for
Plessey code: Start Code and Check Digit.
Syntax: CIdata
Acceptable values for data are:
00 Disabled
10 Plessey with reverse start code
30 Transmit check digit
31 Discard check digit
Default: Disabled
Scan: To disable Plessey:
Disable Plessey
*$+CI00*
*$+CI00*
Or: To set Plessey, complete these steps:
1. Scan this bar code:
Plessey With Reverse Start Code
*$+CI10*
*$+CI10*
2. Scan one of these bar codes to transmit or retain the check digit:
Transmit Check Digit Discard Check Digit
*$+CI30* *$+CI31*
*$+CI30* *$+CI31*