Using the Default Applications
D-7
D
Or: To set the preamble or postamble using the +., ++, or +% reader commands:
1. Scan one of these bar code labels:
Enter Accumulate Mode / Set Preamble A
*+/+.*
*+/+.*
Enter Accumulate Mode / Set Preamble B
*+/++*
*+/++*
Enter Accumulate Mode / Set Postamble C
*+/+%*
*+/+%*
2. Scan a value for
data
from the “Full ASCII Bar Code Chart” in Appendix B. The
preamble or postamble can be from 1 to 25 characters.
3. Scan this bar code:
Exit Accumulate Mode
*-/*
*-/*
4. Repeat Steps 1 to 3 to set another preamble or postamble.
Full ASCII Mode for Code 39
With the
EM9560.BIN
application, you can configure Full ASCII mode for Code 39 using
any of these commands:
• Code 39 configuration command (CB)
• Full ASCII configuration command (RB)
• Enter Full ASCII Mode reader command (+$) and the Exit Full ASCII Mode reader
command (-$)
The last two commands are compatible with the 95XXs. Each command is described
next. For help with the Code 39 configuration command (CB), see Chapter 9,
“Configuration Command Reference.”
Note:
Use the CB configuration command unless your terminals need to be compatible
with the 95XXs in your data collection network.