TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
nugget
D-8
Command: Full ASCII configuration command (RB)
Purpose: Configures the terminal to use Code 39 Full ASCII mode (enabled) or Code 39 Non-Full
ASCII mode (disabled). For a list of ASCII characters, see the “Full ASCII Table” in
Appendix B.
Syntax: RBdata
Acceptable values for data are:
0 Disabled
1Enabled
Scan: One of these bar code labels:
Disable Full ASCII Mode Enable Full ASCII Mode
*$+RB0* *$+RB1*
*$+RB0* *$+RB1*
Command: Enter Full ASCII Mode reader command
Purpose: Enables Code 39 Full ASCII mode so the terminal decodes Code 39 bar code labels by
using a two-character encoding scheme to extend the character set to 128 characters. For
a list of ASCII characters, see the “Full ASCII Table” in Appendix B.
Syntax: +$
Scan:
Full ASCII
*+$*
*+$*
Command: Exit Full ASCII Mode reader command
Purpose: Exits Code 39 Full ASCII mode and puts the terminal in Code 39 Non-Full ASCII mode
(one-character encoding scheme).
Syntax: -$
Scan:
Exit Full ASCII
*/M/D*
*-$*