3. Scan this bar code:
Exit Accumulate Mode
*-/*
*-/*
Scanner Trigger
Purpose: Scanner trigger lets you set level triggering or edge triggering.
• With level triggering, you activate the scanner and the laser turns on and stays on
until you release the button or the trigger on a cabled scanner.
• In edge triggering, you activate the scanner and the laser turns on and stays on. When
you activate the scanner a second time, the laser turns off. Simply releasing the
button or the trigger does not turn the laser off. If the laser is left on, the scanner
timeout turns the laser off.
Syntax: SC
data
Acceptable values for
data
are:
0 Level triggering
1 Edge triggering
Default: Level triggering
Scan: One of these bar codes:
Enable Level Triggering Enable Edge Triggering
*$+SC0* *$+SC1*
*$+SC0* *$+SC1*