TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Co de 39
Nugget
9-34
ISBT Code 128 (continued)
9. Scan one of these bar codes to set distance or time:
Distance Time
*+D* *+T*
*d* *t*
10. Scan this bar code to exit accumulate mode:
Exit Accumulate Mode
*-/*
*-/*
Command Processing
Purpose: Command processing lets you disable or enable reader commands. For example, you can
disable the Backlight command. There are two ways to enable or disable reader
commands:
• Use the Command Processing configuration command described here.
• Use the Reader Command Menu option in the Configuration Menu of the
TRAKKER Antares 2400 Menu System.
You may want to disable reader commands to prevent a user from accidentally entering a
command, or to use data that would otherwise be treated as a command. Any Code 39 or
Code 93 bar code label that contains the 2-character to 4-character commands for
Command Processing is treated as a reader command unless the command is disabled.
If you want to disable or enable several commands, it is easier to use the menu system.
For help, see Chapter 3, “Configuring the Terminal.” For a description of each reader
command that you can enable or disable with Command Processing, see Chapter 8,
“Reader Command Reference.”
Syntax: DCdata
Acceptable values for data are:
0 Disable all reader commands
1 Enable all reader commands
2 Disable override
3 Enable override
command0 Disable reader command
command1 Enable reader command