Co de 39
Nugget
Configuration Command Reference
9-85
9
Example: You want to set a postamble that includes quotation marks. To scan a bar code label that
includes quotation marks, you must configure the terminal to use Code 39 in Full ASCII
mode. For help, see “Code 39” earlier in this chapter.
Enter the postamble by scanning this full ASCII bar code label:
Set Postamble to “B”
*/D/KAE/B/B/BB/B/B/B*
*$+AE"""B"""*
You must enclose the data within quotation marks and precede each quotation mark with
another quotation mark so that the quotation marks are not treated as the end of the data.
Preamble
Purpose: Sets the preamble that precedes any data you scan with the terminal. Common preambles
include a data location number or an operator number.
You can set the preamble to use characters from the extended ASCII character set.
However, you cannot scan in extended ASCII characters in the Preamble command. You
need to use the TRAKKER Antares 2400 Menu System. For help, see “Entering ASCII
Control Characters” in Chapter 3.
Syntax: AD
data
Acceptable values for
data
are up to 25 ASCII characters. When you enter the AD
command without
data
, the preamble is disabled. If you are entering quotation marks as
data or grouping configuration commands, you need to enclose the
data
within quotation
marks (see the example).
Default: No characters (disabled)
Scan: To disable the preamble, scan this bar code:
Disable Preamble
*$+AD*
*$+AD*
Or: To set the preamble to an ASCII character string:
1. Scan this bar code:
Enter Accumulate Mode / Set Preamble
*+/$+AD*
*+/$+AD*